An instance of this function block type extends the local multicast
functionality of the LOADL
function block type by adding a
QI
input. Local publication of the workpiece loading data and event upon
an occurrence of a REQ event is enabled when the
QI
input is true and disabled when it is false.
The default value for the
ID
input (when no parameter value is explicitly connected) is the
function block instance name.
See the TESTBED_MVL.MODEL.CHAIN_MDL
device configuration for an example of the use of an instance of this
function block type.